Distal Medial Humeral Universal Locking Plate (L/R)

Product Details
Customization: Available
Customized: Non-Customized
Certification: ISO, CE
Still deciding? Get samples of US$ 40/Piece
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Distal Medial Humeral Universal Locking Plate (L/R)
  • Distal Medial Humeral Universal Locking Plate (L/R)
  • Distal Medial Humeral Universal Locking Plate (L/R)
Find Similar Products

Basic Info.

Model NO.
2, 4, 6 holes
Condition
New
Usage
Correct Deformities, Fracture Fixation
Using Site
Distal Medial Humerus
Type
Internal Fixation
Product Code
1803
Holes
2, 4, 6 Holes
Length
85 mm (2 Holes), 111mm (4 Holes), 137mm (6 Holes)
Screw Compatibility
Ha 3.5 mm, Locking Screws 2.7/3.5 mm
Applicable Patient Site
Distal Medial Humerus
Material Type Details
Medical-Grade Titanium (Ta3g) for Biocompatibility
Compatibility
Compatible with Ao/Asif System
Surgical Approach
for Distal Medial Humerus Fracture Surgery
Anatomic Fit
for Distal Medial Humerus Stabilization
Biomechanical Properties
High Resistance to Bending and Torsion
Finish
Polished Surface for Reduced Tissue Irritation
Surgical Indication
Humerus Fractures Requiring Surgical Stabilization
Sterility
Non-Sterile, Requires Sterilization Before Use
Reusable or Single-Use
Single-Use Implant
Contraindications
Active Infection at The Surgical Site
Transport Package
1 PC/Package
Specification
Medical grade Titanium
Trademark
BEST MEDICAL
Origin
China
HS Code
9021100000
Production Capacity
500000 PCS/Year

Product Description

Features:
 
  • Anatomical Design: The plate is anatomically contoured for optimal fixation of distal medial humeral fractures, ensuring stability and rigidity during bone healing.
  • Titanium Material: Manufactured from high-strength, biocompatible titanium, ensuring durability and resistance to corrosion while promoting faster healing due to titanium's biocompatibility.
  • Universal Design: Available in both long and short versions, allowing for flexibility in treating various types of fractures based on patient anatomy and fracture location.
  • Multiple Hole Configurations: Offered in 2, 4, and 6-hole versions, providing flexible screw placement options based on fracture type and fixation needs.
  • Locking Screws Compatibility: Compatible with HA 3.5 mm screws and locking screws 2.7 mm/3.5 mm, ensuring stable fixation.
  • Bilateral Use: Designed for both left (L) and right (R) humerus to accommodate different anatomical requirements.

Intended Use:

The Distal Medial Humeral Universal Locking Plate (L/R) is intended for the surgical treatment of distal humeral fractures, particularly on the medial side. It provides rigid stabilization to promote proper bone healing in cases of trauma, fractures, or deformities of the humerus.

Indications:
 
  • Distal medial humeral fractures requiring surgical stabilization.
  • Humeral metaphysis fractures or fractures extending into the diaphysis.
  • Comminuted, oblique, or spiral fractures of the distal humerus.
  • Non-union or malunion fractures of the humerus.
  • Open or closed fractures requiring rigid fixation with locking screws.

Contraindications:
 
  • Active infection at the surgical site.
  • Severe osteoporosis or insufficient bone stock for secure fixation.
  • Known allergies to titanium or other implant materials.
  • Fractures that can be treated non-surgically or without the need for surgical intervention.
 
Product Parameters Table:
 
Parameter Details
Product Name Distal Medial Humeral Universal Locking Plate (L/R)
Material High-strength, biocompatible titanium
Surface Treatment Polished or anodized for enhanced corrosion resistance
Plate Type Universal locking plate for distal medial humerus fractures
Available Versions Long and Short
Holes Configuration 2, 4, 6 holes
Long Plate Length (mm) 85 mm (2 holes), 111 mm (4 holes), 137 mm (6 holes)
Short Plate Length (mm) 82 mm (2 holes), 108 mm (4 holes), 134 mm (6 holes)
Screw Compatibility HA 3.5 mm, Locking screws 2.7 mm / 3.5 mm
Indications Distal humeral fractures, non-union, malunion
Contraindications Active infection, poor bone quality, allergies to titanium
Sterilization Method Provided in unsterile packaging, requires sterilization before surgery
Fixation Type Rigid fixation using locking screws
Intended Surgical Approach Open reduction and internal fixation (ORIF) for humerus fractures
Packaging Unsterile packaging, requires sterilization before use
CE Certification Certified for use in multiple international markets (CE compliant)
Shelf Life 5 years when stored in appropriate conditions
Radiolucency Compatible with imaging modalities like X-ray, CT
Customization Available in different lengths and configurations for patient-specific needs
Usage Environment Operating room, under sterile conditions

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now