Distal Anterior and Posterior Tibial T Universal Locking Plate

Product Details
Customization: Available
Customized: Non-Customized
Certification: ISO, CE
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (14)
Find Similar Products
  • Overview
  • Product Description
  • Indications
  • Contraindications
  • Product Parameters
  • Inside Our Company
Overview

Basic Info.

Model NO.
4, 5, 6 holes
Condition
New
Usage
Correct Deformities, Fracture Fixation
Using Site
Distal Tibia
Type
Internal Fixation
Product Code
3803
Holes
4, 5, 6 Holes
Length
72 mm, 80 mm, 90 mm
Screw Compatibility
Ha 3.5mm Screws, Locking Screw 3.5mm
Applicable Patient Site
Distal Tibial Fractures
Material Type Details
Medical-Grade Titanium (Ta3g) for Biocompatibility
Compatibility
Compatible with Ao/Asif System
Surgical Approach
for Distal Tibial Fractures
Anatomic Fit
for Distal Tibial Fractures
Biomechanical Properties
High Resistance to Bending and Torsion
Finish
Polished Surface for Reduced Tissue Irritation
Surgical Indication
Distal Tibial Fracture Requiring Surgery
Sterility
Non-Sterile, Requires Sterilization Before Use
Reusable or Single-Use
Single-Use Implant
Contraindications
Active Infection at The Surgical Site
Transport Package
1 PC/Package
Specification
Medical grade Titanium
Trademark
BEST MEDICAL
Origin
China
HS Code
9021100000
Production Capacity
500000 PCS/Year

Product Description

Product Description

Material: Medical-grade titanium


Features
  • Constructed from high-quality titanium for superior strength, biocompatibility, and corrosion resistance.
  • T-type universal design allows for versatile fixation of both anterior and posterior distal tibial fractures.
  • Available in multiple hole configurations (4 to 6 holes) and lengths of 72 mm to 90 mm, providing flexibility for various fracture types.
  • Compatible with HA 2.4 mm and 2.7 mm screws and locking screws for secure fixation.
  • Pre-contoured for an anatomical fit, promoting effective fracture stabilization with minimal soft tissue irritation.
  • Polished and anodized surface treatment enhances resistance to corrosion and ensures longevity of the implant.
Indications

Intended Use

The Distal Tibial Anterior and Posterior T-type Universal Locking Plate is designed for the fixation of distal tibial anterior and posterior fractures. It provides rigid stabilization and assists in proper alignment during the healing process.

Indications
  • Distal tibial anterior fractures
  • Distal tibial posterior fractures
  • Osteotomies of the distal tibia
  • Nonunions and malunions of the distal tibia
  • Post-traumatic deformities requiring distal tibial stabilization
Contraindications

 

Contraindications
  • Active infection or inflammation at the surgical site
  • Severe osteoporosis or inadequate bone quality
  • Known hypersensitivity to titanium or implant materials
  • Inadequate bone support for secure screw fixation
  • Skeletally immature patients
 
Product Parameters

 

Product Parameters Table
Parameter Details
Product Name Distal Tibial Anterior and Posterior T-type Universal Locking Plate
Material Medical-grade titanium
Surface Treatment Polished and anodized for corrosion resistance and minimal soft tissue irritation
Plate Type T-type universal locking plate for distal tibial fractures
Available Versions Left and right configurations available
Holes Configuration 4, 5, 6 holes
Length (mm) 72 mm, 80 mm, 90 mm
Screw Compatibility HA 2.4 mm, 2.7 mm screws, Locking screws 2.4/2.7 mm
Indications Distal tibial anterior and posterior fractures, osteotomies, nonunions
Contraindications Active infection, poor bone quality, titanium allergies
Sterilization Method Supplied unsterile, requires sterilization prior to use
Fixation Type Rigid fixation using locking and standard screws
Intended Surgical Approach Open reduction and internal fixation (ORIF) for distal tibial fractures
Packaging Non-sterile packaging, requires sterilization before use
CE Certification Certified for use in multiple international markets (CE compliant)
Shelf Life 5 years when stored under appropriate conditions
Radiolucency Radiolucent for use with imaging modalities like X-ray and CT
Customization Available in different lengths and configurations for patient-specific needs
Usage Environment Designed for sterile operating room conditions

Inside Our Company

Distal Anterior and Posterior Tibial T Universal Locking PlateDistal Anterior and Posterior Tibial T Universal Locking PlateDistal Anterior and Posterior Tibial T Universal Locking PlateDistal Anterior and Posterior Tibial T Universal Locking PlateDistal Anterior and Posterior Tibial T Universal Locking Plate

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier