Distal Posterior Tibial T Locking Plate

Product Details
Customization: Available
Customized: Non-Customized
Certification: ISO, CE
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (14)
  • Distal Posterior Tibial T Locking Plate
  • Distal Posterior Tibial T Locking Plate
Find Similar Products
  • Overview
  • Product Description
  • Indications
  • Contraindications
  • Product Parameters
  • Inside Our Company
Overview

Basic Info.

Model NO.
3, 5 holes
Condition
New
Usage
Correct Deformities, Fracture Fixation
Using Site
Distal Posterior Tibial Fractures
Type
Internal Fixation
Product Code
4402
Holes
3, 5 Holes
Length
64 mm, 90 mm
Screw Compatibility
Ha 3.5 mm, Locking Screws 3.5 mm
Applicable Patient Site
Distal Posterior Tibial Fractures, Osteotomies
Material Type Details
Medical-Grade Titanium (Ta3g) for Biocompatibility
Compatibility
Compatible with Ao/Asif System
Surgical Approach
for Distal Posterior Tibial Fractures, Osteotomies
Anatomic Fit
for Distal Posterior Tibial Fractures, Osteotomies
Biomechanical Properties
High Resistance to Bending and Torsion
Finish
Polished Surface for Reduced Tissue Irritation
Surgical Indication
Distal Posterior Tibial Fracture Requiring Surgery
Sterility
Non-Sterile, Requires Sterilization Before Use
Reusable or Single-Use
Single-Use Implant
Contraindications
Active Infection at The Surgical Site
Transport Package
1 PC/Package
Specification
Medical grade Titanium
Trademark
BEST MEDICAL
Origin
China
HS Code
9021100000
Production Capacity
500000 PCS/Year

Product Description

Product Description

 

Material: Medical-grade titanium

Features
  • Constructed from high-strength, biocompatible medical-grade titanium for superior durability.
  • The plate is designed to accommodate HA 3.5 mm and locking screws 3.5 mm, ensuring secure fixation.
  • Anatomically contoured to fit the posterior aspect of the distal tibia, providing optimized fixation and minimal soft tissue irritation.
  • Surface treatment includes polishing and anodizing for enhanced corrosion resistance and a smooth finish that reduces tissue irritation.
  • Offers stability for complex fractures with multiple screw holes for effective fixation.
Indications

 

Intended Use
The Distal Posterior Tibial T Locking Plate is designed for the management of fractures in the distal posterior tibia, specifically requiring T-shaped plating for better stability and load distribution.

Indications
  • Fractures of the distal posterior tibia
  • Osteotomies and bone malunions requiring rigid fixation in the posterior tibia
  • Nonunion fractures in the posterior tibia
  • Complex fractures with multi-fragment patterns
Contraindications

 

Contraindications
  • Active infections in the surgical area
  • Severe osteoporosis or poor bone quality unsuitable for screw fixation
  • Allergies or sensitivities to titanium-based materials
  • Insufficient bone stock for effective screw placement
 
Product Parameters

 

Product Parameters Table for Distal Posterior Tibial T Locking Plate
Parameter Details
Product Name Distal Posterior Tibial T Locking Plate
Material Medical-grade titanium
Surface Treatment Polished and anodized for corrosion resistance and tissue compatibility
Plate Type T-shaped locking plate for distal posterior tibial fractures
Available Versions Universal design, available for both left and right sides
Holes Configuration 3, 5 holes
Length (mm) 64 mm, 90 mm
Screw Compatibility HA 3.5 mm, Locking screws 3.5 mm
Indications Distal posterior tibial fractures, osteotomies, and nonunion fractures
Contraindications Active infection, poor bone quality, titanium allergies
Sterilization Method Supplied unsterile, requires sterilization prior to surgery
Fixation Type Rigid fixation using locking screws
Intended Surgical Approach Open reduction and internal fixation (ORIF)
Packaging Non-sterile packaging, sterilization required before use
CE Certification CE certified for international markets
Shelf Life 5 years under appropriate storage conditions
Radiolucency Radiolucent for imaging support during surgery
Customization Available in different lengths and configurations
Usage Environment Sterile operating room environment
 
Inside Our Company

Distal Posterior Tibial T Locking PlateDistal Posterior Tibial T Locking PlateDistal Posterior Tibial T Locking PlateDistal Posterior Tibial T Locking PlateDistal Posterior Tibial T Locking Plate

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier